LCD Sharp Alexander 22” hidup sebentar terus mati

 KASUS :
  • LCD Sharp Alexander 22” MODEL LC22L10
  • Jika dihidupkan (led nyala hijau) ada raster nyala sebentar, kemudian terus mati sendiri dan lampu led nyala merah.
  • Jika tombol power ditekan lagi, maka kejadian seperti diatas akan terulang lagi.
  • Setelah diulang 3 atau 4 kali akhirnya pesawat akan mati protek dan led merah kedip 2x secara berulang. Pesawat baru akan dapat dihidupkan lagi setelah colokan listrik dilepas terlebih dahulu.

SOLUSI :
  • Led merah kedip 2x kalau Sharp LCD hal ini menunjukkan problem pada bagian inverter.
  • Saat backlight menyala coba dilakukan pengukuran tegangan-tegangan pada kapasitor output tegangan tinggi setiap tranfo inverter (ada 4 buah output). Pengukuran dilakukan pada kapistor milar yang berhubungan dengan pin-1 diode D8 seperti contoh gambar dibawah. JANGAN MELAKUKAN PENGUKURAN PADA PIN-4 TRANFO INVERTER ATAU PIN-1 CN2 KONEKTOR LAMPU BACKLIGHT, KARENA TEGANGAN SANGAT TINGGI !
  • Ternyata hasilnya salah satu tranfo tegangannya ada yang lebih rendah dibanding dengan ke-3 tranfo lainnya.
  • Pada tranfo yang bermasalah ketika coba diukur resistansinya pada pin-3/4, ternyata lebih besar jika dibanding dengan ke-3 tranfo lainnya
clip_image002Gambar bukan skema sebenarnya (hanya untuk memudahkan penjelasan saja)
  • Pada kasus ini kami coba putus jalur ERROR dari pcb Inverter ke Main-pcb (posisi pada kabel konektor yang dekat ground), ternyata pesawat dapat hidup terus, ada suara dan lampu led tetap nyala hijau terus,  tetapi lampu backlight tetap mati lagi sehingga raster menjadi gelap
  • Kesimpulan problem disebabkan kerusakan pada salah satu tranfo inverter yang menyebabkan over-current protek (OCP)

Alexander Sharp LCD 22 "briefly kept alive dead


CASE:

  • Alexander Sharp LCD 22 "MODEL LC22L10
  • If turned on (led green flame) No raster flame briefly, then continued off and then the red LED lights flash.
  • If the power button is pressed again, the events such as the above will be repeated again.
  • After repeated 3 or 4 times the aircraft will eventually die protectionism and red LED blink 2x repeatedly. The tv will be turned on again after the power jack removed first.


SOLUTION:

  • 2x red blinking LED that Sharp LCD indicating a problem in the inverter.
  • When the backlight turns on trying to do the measurement of voltages on the high voltage output capacitors each tranfo inverter (4 pieces output). Measurements were taken at kapistor mylar associated with pin-1 diode D8 as the example shown below. DO NOT MEASUREMENT OF PIN-4 tranfo INVERTER OR PIN-1 CONNECTOR CN2 BACKLIGHT LAMPS, FOR VERY HIGH VOLTAGE!
  • It turns out one of the voltage tranfo no lower than 3rd tranfo other.
  • At tranfo problematic when trying to measure the resistance at pin-3/4, was greater when compared with all other 3 tranfo



Picture not actual schema (only for ease of explanation only)
  • In this case we try to break up the path of pcb ERROR Inverter to Main-pcb (position on the cable connectors are near the ground), it turns out the aircraft can survive, no noise and flame green LED lights remain on, but the backlight lights remain off again so raster dark
  • Conclusion problem caused damage to one of tranfo inverter over-current which causes Protek (OCP)





sumber: